Standardized Benchmark Dataset for Localized Exposure to a Realistic Source at 10-90 GHz

05/03/2023
by   Ante Kapetanovic, et al.
0

The lack of freely available standardized datasets represents an aggravating factor during the development and testing the performance of novel computational techniques in exposure assessment and dosimetry research. This hinders progress as researchers are required to generate numerical data (field, power and temperature distribution) anew using simulation software for each exposure scenario. Other than being time consuming, this approach is highly susceptible to errors that occur during the configuration of the electromagnetic model. To address this issue, in this paper, the limited available data on the incident power density and resultant maximum temperature rise on the skin surface considering various steady-state exposure scenarios at 10-90 GHz have been statistically modeled. The synthetic data have been sampled from the fitted statistical multivariate distribution with respect to predetermined dosimetric constraints. We thus present a comprehensive and open-source dataset compiled of the high-fidelity numerical data considering various exposures to a realistic source. Furthermore, different surrogate models for predicting maximum temperature rise on the skin surface were fitted based on the synthetic dataset. All surrogate models were tested on the originally available data where satisfactory predictive performance has been demonstrated. A simple technique of combining quadratic polynomial and tensor-product spline surrogates, each operating on its own cluster of data, has achieved the lowest mean absolute error of 0.058 C. Therefore, overall experimental results indicate the validity of the proposed synthetic dataset.

READ FULL TEXT

page 1

page 2

page 3

page 4

research
08/20/2019

Sensor-Based Estimation of Dim Light Melatonin Onset (DLMO) Using Features of Two Time Scales

Circadian rhythms govern most essential biological processes in the huma...
research
11/17/2017

Modelling dark current and hot pixels in imaging sensors

A gaussian mixture model was fitted to experimental data recorded under ...
research
07/08/2019

Surrogate modeling of indoor down-link human exposure based on sparse polynomial chaos expansion

Human exposure induced by wireless communication systems increasingly dr...
research
05/18/2022

Power Module Heat Sink Design Optimization with Ensembles of Data-Driven Polynomial Chaos Surrogate Models

We consider the problem of optimizing the design of a heat sink used for...
research
03/08/2023

High Fidelity Synthetic Face Generation for Rosacea Skin Condition from Limited Data

Similar to the majority of deep learning applications, diagnosing skin d...
research
03/21/2023

Exposure Assessment for Wearable Patch Antenna Arrays at Millimeter Waves

Since the spread of the wearable systems and the implementation of the f...
research
07/07/2017

Skin Temperature Measurement

This report represents the design and implementation of a skin temperatu...

Please sign up or login with your details

Forgot password? Click here to reset