Efficient Low Dose X-ray CT Reconstruction through Sparsity-Based MAP Modeling

02/08/2014
by   SayedMasoud Hashemi, et al.
0

Ultra low radiation dose in X-ray Computed Tomography (CT) is an important clinical objective in order to minimize the risk of carcinogenesis. Compressed Sensing (CS) enables significant reductions in radiation dose to be achieved by producing diagnostic images from a limited number of CT projections. However, the excessive computation time that conventional CS-based CT reconstruction typically requires has limited clinical implementation. In this paper, we first demonstrate that a thorough analysis of CT reconstruction through a Maximum a Posteriori objective function results in a weighted compressive sensing problem. This analysis enables us to formulate a low dose fan beam and helical cone beam CT reconstruction. Subsequently, we provide an efficient solution to the formulated CS problem based on a Fast Composite Splitting Algorithm-Latent Expected Maximization (FCSA-LEM) algorithm. In the proposed method we use pseudo polar Fourier transform as the measurement matrix in order to decrease the computational complexity; and rebinning of the projections to parallel rays in order to extend its application to fan beam and helical cone beam scans. The weight involved in the proposed weighted CS model, denoted by Error Adaptation Weight (EAW), is calculated based on the statistical characteristics of CT reconstruction and is a function of Poisson measurement noise and rebinning interpolation error. Simulation results show that low computational complexity of the proposed method made the fast recovery of the CT images possible and using EAW reduces the reconstruction error by one order of magnitude. Recovery of a high quality 512× 512 image was achieved in less than 20 sec on a desktop computer without numerical optimizations.

READ FULL TEXT

page 8

page 10

research
06/15/2019

An Exact and Fast CBCT Reconstruction via Pseudo-Polar Fourier Transform based Discrete Grangeat's Formula

The recent application of Fourier Based Iterative Reconstruction Method ...
research
07/10/2017

Low Dose CT Image Reconstruction With Learned Sparsifying Transform

A major challenge in computed tomography (CT) is to reduce X-ray dose to...
research
12/04/2014

Statistical models and regularization strategies in statistical image reconstruction of low-dose X-ray CT: a survey

Statistical image reconstruction (SIR) methods have shown potential to s...
research
06/17/2021

AI-Enabled Ultra-Low-Dose CT Reconstruction

By the ALARA (As Low As Reasonably Achievable) principle, ultra-low-dose...
research
03/05/2021

Interpolation of CT Projections by Exploiting Their Self-Similarity and Smoothness

As the medical usage of computed tomography (CT) continues to grow, the ...
research
12/11/2019

RODEO: Robust DE-aliasing autoencOder for Real-time Medical Image Reconstruction

In this work we address the problem of real-time dynamic medical MRI and...
research
01/29/2016

Joint System and Algorithm Design for Computationally Efficient Fan Beam Coded Aperture X-ray Coherent Scatter Imaging

In x-ray coherent scatter tomography, tomographic measurements of the fo...

Please sign up or login with your details

Forgot password? Click here to reset