MAVIREC: ML-Aided Vectored IR-DropEstimation and Classification
Vectored IR drop analysis is a critical step in chip signoff that checks the power integrity of an on-chip power delivery network. Due to the prohibitive runtimes of dynamic IR drop analysis, the large number of test patterns must be whittled down to a small subset of worst-case IR vectors. Unlike the traditional slow heuristic method that select a few vectors with incomplete coverage, MAVIREC uses machine learning techniques – 3D convolutions and regression-like layers – for accurately recommending a larger subset of test patterns that exercise worst-case scenarios. In under 30 minutes, MAVIREC profiles 100K-cycle vectors and provides better coverage than a state-of-the-art industrial flow. Further, MAVIREC's IR drop predictor shows 10x speedup with under 4mV RMSE relative to an industrial flow.