Spatio-Temporal Deep Learning-Based Undersampling Artefact Reduction for 2D Radial Cine MRI with Limited Data

04/01/2019
by   Andreas Kofler, et al.
0

In this work we reduce undersampling artefacts in two-dimensional (2D) golden-angle radial cine cardiac MRI by applying a modified version of the U-net. We train the network on 2D spatio-temporal slices which are previously extracted from the image sequences. We compare our approach to two 2D and a 3D Deep Learning-based post processing methods and to three iterative reconstruction methods for dynamic cardiac MRI. Our method outperforms the 2D spatially trained U-net and the 2D spatio-temporal U-net. Compared to the 3D spatio-temporal U-net, our method delivers comparable results, but with shorter training times and less training data. Compared to the Compressed Sensing-based methods kt-FOCUSS and a total variation regularised reconstruction approach, our method improves image quality with respect to all reported metrics. Further, it achieves competitive results when compared to an iterative reconstruction method based on adaptive regularization with Dictionary Learning and total variation, while only requiring a small fraction of the computational time. A persistent homology analysis demonstrates that the data manifold of the spatio-temporal domain has a lower complexity than the spatial domain and therefore, the learning of a projection-like mapping is facilitated. Even when trained on only one single subject without data-augmentation, our approach yields results which are similar to the ones obtained on a large training dataset. This makes the method particularly suitable for training a network on limited training data. Finally, in contrast to the spatial 2D U-net, our proposed method is shown to be naturally robust with respect to image rotation in image space and almost achieves rotation-equivariance where neither data-augmentation nor a particular network design are required.

READ FULL TEXT

page 1

page 4

page 7

page 8

page 10

page 11

page 12

research
07/24/2023

Unsupervised reconstruction of accelerated cardiac cine MRI using Neural Fields

Cardiac cine MRI is the gold standard for cardiac functional assessment,...
research
01/25/2021

Spatio-temporal Data Augmentation for Visual Surveillance

Visual surveillance aims to stably detect a foreground object using a co...
research
02/10/2020

Unsupervised Adaptive Neural Network Regularization for Accelerated Radial Cine MRI

In this work, we propose an iterative reconstruction scheme (ALONE - Ada...
research
08/23/2018

Left ventricle quantification through spatio-temporal CNNs

Cardiovascular diseases are among the leading causes of death globally. ...
research
06/15/2022

A Projection-Based K-space Transformer Network for Undersampled Radial MRI Reconstruction with Limited Training Subjects

The recent development of deep learning combined with compressed sensing...
research
06/15/2021

Cine-MRI detection of abdominal adhesions with spatio-temporal deep learning

Adhesions are an important cause of chronic pain following abdominal sur...
research
02/26/2019

Deep MR Fingerprinting with total-variation and low-rank subspace priors

Deep learning (DL) has recently emerged to address the heavy storage and...

Please sign up or login with your details

Forgot password? Click here to reset